■ General
WGLF series magnetic float level gauge is widely used in petroleum, chemical industry, pharmacy, metallurgy, sugar making, paper making, power, water treatment, shipping, environmental protection, boiler and other industries to detect and control the medium level in various tanks, tanks, towers and other containers (equipment). The liquid level gauge has incomparable advantages over the traditional glass tube (plate) liquid level gauge. Because its indicating part does not contact with the measured medium, it can achieve high sealing. It is more reliable and safe for high-temperature, high-pressure, toxic, harmful and strongly corrosive media.
The magnetic float level gauge takes the float as the measuring element, and transmits the liquid level linearly to the field magnetic turnover indicator through the magnetic coupling of the magnetic steel, so that the indicator can clearly indicate the height of the liquid level. The liquid level meter can be equipped with a liquid level alarm and a liquid level remote transmission device. The liquid level alarm realizes the upper and lower limit control, limit alarm and accident interlock of the liquid level. The remote transmission device of the liquid level linearly converts the change of the liquid level into a DC 4~20mA current signal output, which is used to connect with the digital display instrument or computer system to achieve remote liquid level display and control.
■ Product characteristics
● Simple design, durable, reliable operation, and visual display of liquid level
● The measurement display and signal output parts are completely sealed and isolated from the medium, safe and reliable
● Large measurement range, no blind area in the whole process of measurement, large character scale, intuitive, eye-catching and easy to read
● The display unit and alarm switch work without power supply
● Reliable and durable without special maintenance
● It has the advantages of convenient installation, small maintenance and low maintenance cost. It is an upgraded product of glass tube and glass plate level gauge
● Suitable for continuous measurement of liquid level of various high-temperature, high-pressure, corrosive, flammable and explosive media
■ Technical specifications
Technical parameters of the whole machine
● Measuring range: 300~0000mm
● Indication error: ± 10mm
● Working pressure: standard type ≤ 1.6MPa, high-pressure type ≤ 10.0MPa, PVC ≤ 1.0MPa
● Medium temperature: standard type: - 20 ° C~150 ° C High temperature type: ≤ 450 ° C PVC: - 20 ° C~60 ° C
● Medium density: ≥ 0.40g/cm ³
● Medium density difference (measuring interface): 0.15g/cm ³
● Medium viscosity: ≤ 150cP
● Liquid receiving material: determined according to the medium (1Cr18Ni9Ti, 316L, PTFE, PP, PE, etc.)
● Connecting flange: side mounted JB/T 81-1994 DN20 PN1.0 PN1.6 PN2.5
Side mounted JB/T 82.2-1994 DN20 PN4.0
Top mounted JB/T 81-1994 DN150 PN1.6
● Blowdown interface: ZG1/2 "(blow down valve), M20X1.5 (blow down blockage)
● Insulation jacket joint: G 1/2 "(outside)
● Environmental vibration: frequency ≤ 25HZ, amplitude ≤ 0.5mm
● Follow speed: ≤ 0.08m/s
● Float material: basic 1Cr18Ni9Ti, 304, 316L
Plastic PVC, PP, PE
Special Ti (used in medium with low density and high pressure)
● Body material: 1Cr18Ni9Ti, 304, 316L, PVC (polyvinyl chloride), PP (polypropylene), PE (polyethylene)
Remote mount H (dry spring resistance type)
● Measuring range: 300~0000mm (or as required by users)
● Accuracy: ± 10mm (absolute error)
● Return difference: ± 10mm
● Power supply: 24V DC ± 5% two-wire system
● Output signal: 4~20mA DC two-wire system
● Ambient temperature: - 40~60 ℃
● Load capacity: 500 Ω (under 24V DC power supply)
● Electrical interface: M20X1.5 (internal) or as required by users
● Enclosure protection: IP65
● Explosion proof type: explosion-proof dIIBT4
Alarm switch
● Contact capacity: 220V AC/DC 2A (flameproof type, common type)
● Switch hysteresis: 18mm
● Service life of switch: 105 times
● Ambient temperature: - 40~125 ℃
● Electrical interface: M20X1.5 (internal) or as required by users
● Enclosure protection: IP65
● Explosion proof type: explosion-proof dIIBT4
■ Model Selection
■ Ordering instructions
● When ordering, fill in according to the type spectrum specified by the manufacturer
● When the process interface is flange type, the ordering party must provide the relevant specifications of the interface flange
● The factory can supply complete sets of secondary display instruments matched with liquid level gauges