■ General
WGLDY series impulse liquid level gauge is a liquid level measuring instrument composed of pressure sensor, gas collector assembly and impulse pipe assembly. When the gas collecting cylinder sinks into the measured liquid, the air in the gas collecting cylinder is subjected to the pressure of the measured liquid, and the pressure is transmitted to the pressure measuring sensitive element through the impulse pipe, diaphragm and silicone oil. At this time, the pressure on the sensitive element is:
Where: P=0.0098 p h+Pc Pb
P - pressure of sensor (MPa)
ρ - Density of liquid (g/cm2 or T/m2)
H - depth of liquid level to be measured (m)
Pc Liquid level pressure (MPa)
Pb - back pressure of sensing element (MPa)
When measuring the open vessel (Pc=0) and the back pressure of the sensing element is connected to the atmosphere (Pb=Pc), P=0.0098 p h means that the output signal of the pressure transmitter is proportional to the density of the liquid to be measured and the detection depth of the liquid.
The conductive liquid level gauge is not affected by medium bubbling, deposition, turbidity, etc., and has no operating parts, so it is easy to install and maintain. It is especially suitable for measuring liquid level in metallurgy, power, paper making, petroleum, chemical and other industries.
■ Product characteristics
● The sensor does not contact with the detection medium, and has high long-term working reliability and stability
● It is applicable to highly corrosive measurement conditions, and is not affected by medium foaming, deposition, turbidity, etc
● No moving parts, simple installation and maintenance
■ Technical specifications
● Power supply: DC24V
● Accuracy: ± 1.0%
● Measuring range: 0-1-20m
● Ambient temperature: - 10C~70C
● Output signal: DC 4~20mA (two-wire system)
● Load resistance:<600 Ω
■ Model Selection
■ Ordering instructions
● When ordering, fill in according to the type spectrum specified by the manufacturer
● When the process interface is flange type, the ordering party must provide the relevant specifications of the interface flange
● The factory can supply complete sets of secondary display instruments matched with liquid level gauges
● When the Demander has special requirements for measurement, the Supplier and the Demander shall discuss with each other