■ General
WGS-C series dust monitor is mainly used for online measurement under the following working conditions:
● Bag damage monitoring (WGS-C1)
● Trend monitoring and tracking (WGS-C3)
● Dust concentration measurement (WGS - C4/C5)
■ Technical parameters
● Measuring medium: suspended solids in the air stream
● Dust particles: 0.3 μ M or more
● Measurement range: 0.1mg/m °~1kg/m
● Accuracy: ± 5% of measured value
● Process conditions: temperature: 300 ° C (standard)/400-800 ° C (optional)
Pressure: 200 kPa (standard)/up to 6 MPa (optional)
Flue gas velocity: minimum 4 m/s
Humidity: 95% RH or less (non condensing)
● Input voltage impulse: z greater than 100 V
● Damping time: 10 to 180 seconds
● Output signal: isolation 4-20mA (C3/C4/C5); Relay 5 A, 24 V AC or DC; RS232/485 interface (C4/C5)
● Environmental conditions: temperature - 20~+45 ° C; Humidity 95% RH or less (non condensing); Vibration 5m/S or less
● Material: probe: 316 stainless steel; Probe insulation: Teflon (high temperature: PEEK or ceramic); Shell: die-casting aluminum
● Power supply and power: 115 VAC/230 VAC, 50/60Hz; Power 3 W
● Electrical interface: DIN PG11 power line: DIN PG11 signal line.
● Weight: 2.3 kg
● Alarm setting selection: automatic setting of alarm value (two setting methods), factory setting (depending on the average measured value)
● Explosion proof: sensor intrinsically safe explosion-proof EExiaIICT6, transmitter EExdIIBT6.